Espressif Systems /ESP32-C6 /MCPWM0 /FH0_CFG0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FH0_CFG0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (TZ0_SW_CBC)TZ0_SW_CBC 0 (TZ0_F2_CBC)TZ0_F2_CBC 0 (TZ0_F1_CBC)TZ0_F1_CBC 0 (TZ0_F0_CBC)TZ0_F0_CBC 0 (TZ0_SW_OST)TZ0_SW_OST 0 (TZ0_F2_OST)TZ0_F2_OST 0 (TZ0_F1_OST)TZ0_F1_OST 0 (TZ0_F0_OST)TZ0_F0_OST 0TZ0_A_CBC_D 0TZ0_A_CBC_U 0TZ0_A_OST_D 0TZ0_A_OST_U 0TZ0_B_CBC_D 0TZ0_B_CBC_U 0TZ0_B_OST_D 0TZ0_B_OST_U

Description

Actions on PWM0A and PWM0B trip events

Fields

TZ0_SW_CBC

Enable register for software force cycle-by-cycle mode action. 0: disable, 1: enable

TZ0_F2_CBC

event_f2 will trigger cycle-by-cycle mode action. 0: disable, 1: enable

TZ0_F1_CBC

event_f1 will trigger cycle-by-cycle mode action. 0: disable, 1: enable

TZ0_F0_CBC

event_f0 will trigger cycle-by-cycle mode action. 0: disable, 1: enable

TZ0_SW_OST

Enable register for software force one-shot mode action. 0: disable, 1: enable

TZ0_F2_OST

event_f2 will trigger one-shot mode action. 0: disable, 1: enable

TZ0_F1_OST

event_f1 will trigger one-shot mode action. 0: disable, 1: enable

TZ0_F0_OST

event_f0 will trigger one-shot mode action. 0: disable, 1: enable

TZ0_A_CBC_D

Cycle-by-cycle mode action on PWM0A when fault event occurs and timer is decreasing. 0: do nothing, 1: force low, 2: force high, 3: toggle

TZ0_A_CBC_U

Cycle-by-cycle mode action on PWM0A when fault event occurs and timer is increasing. 0: do nothing, 1: force low, 2: force high, 3: toggle

TZ0_A_OST_D

One-shot mode action on PWM0A when fault event occurs and timer is decreasing. 0: do nothing, 1: force low, 2: force high, 3: toggle

TZ0_A_OST_U

One-shot mode action on PWM0A when fault event occurs and timer is increasing. 0: do nothing, 1: force low, 2: force high, 3: toggle

TZ0_B_CBC_D

Cycle-by-cycle mode action on PWM0B when fault event occurs and timer is decreasing. 0: do nothing, 1: force low, 2: force high, 3: toggle

TZ0_B_CBC_U

Cycle-by-cycle mode action on PWM0B when fault event occurs and timer is increasing. 0: do nothing,1: force low, 2: force high, 3: toggle

TZ0_B_OST_D

One-shot mode action on PWM0B when fault event occurs and timer is decreasing. 0: do nothing, 1: force low, 2: force high, 3: toggle

TZ0_B_OST_U

One-shot mode action on PWM0B when fault event occurs and timer is increasing. 0: do nothing, 1: force low, 2: force high, 3: toggle

Links

() ()